UPS On-Line a Double Conversion
model SKUDO ONE IOT 40
Nominal power 4 kVAi / 2.85 kVA / 2 kWatt

Applications:
                            

Availability: 20

Order fulfillment within 8 working hours

compare Compare

Description

Double conversion on-line technology UPS with By-Pass in compliance with ENV 50091-3, ensures a constantly powered load and zero intervention time.
This is the only technology that allows the total elimination of electrical disturbances as it does not require any direct network-user connection.
Totally managed by microprocessors, it feeds the utilities with a perfect sinusoidal waveform without any interruption.
Thanks to the USB 2.0 HID and RS232 interfaces and the WinPower Management/Control Software, which is available free of charge on our website in the download section, total management and control of the UPS is possible with the main operating systems.
It guarantees the highest quality standard (CE, UL, ISO9001, etc.) and is approved by the most important computer and operating system manufacturers.
It has a 2-year guarantee and is always ready for delivery.
The refined and functional design, the silence, the reduced weights and dimensions, the use of recyclable materials, make SKUDO an ideal choice for the safety of all offices.

Advantages

  • Output power factor ONE, that is 1kVA = 1kW
  • Built-in IOT (Internet Of Things) module as standard
  • Ethernet port for standard IOT solution
  • IEC 62443 certification for computer security
  • Input power factor correction ≧ 0.99
  • Operation in ECO Mode for energy saving
  • Operation as a 50/60 Hz frequency converter
  • Ignition in the absence of the electricity network (cold start)
  • Output voltage selectable directly from the display among the following values: 200; 208; 220; 230; 240 Vac
  • Protection against voltage discharges, radio interference (EMI/RFI filters), short circuits, overloads
  • Fast battery charging (Advanced Battery Management) even for long autonomy via an additional 3.5A battery charger (optional)
  • Automatic recharge of the batteries even with the UPS off to prolong the life of the batteries
  • Autonomy extensions through special Battery Packs with the same design as the UPS
  • Liquid Crystal Display (LCD) with 10 selectable languages
  • Wireless dongle (optional)
  • RS232 and USB 2.0 HDI communication interface
  • SNMP interface (optional)
  • AS400 interface (optional)
  • RS485 interface (optional)
  • Temperature and humidity sensor interface (optional)

Data Sheet

 Model SKUDO ONE IOT 40
 Technology On-Line Double Conversion
 Power
 Computer technology (VA) 4.000
 Electric (VA) 2.850
 Electric (W) 2.000
 Input
 Phases Single Phase + Earth
 Voltage tolerance (Vac) from 160 to 300
 Nominal frequency (Hz) 50 or 60
 Frequency tolerance (Hz) from 40 to 70
 Power factor (cosfì) ≧0.99
 Total Harmonic Distortion (%) ≦ 5
 Connection socket 1 x IEC C14
 Number of cables supplied 1
 Output
 Selectable voltage (Vac) 200 / 208 / 220 / 230 / 240
 Voltage tolerance ±1% in battery mode
 Frequency (Hz) 50 or 60
 Maximum Power Factor (P.F.) 1
 Current at 230 Vac (A) 8.7
 Waveform Sinusoidal
 Maximum crest factor 3:1
 Total Harmonic Distortion (THD)  ≦1% with linear load - ≦5% with no linear load
 Overload in battery mode and with ambient temperature ≦35°C >105% - ≦ 125%: UPS shuts down after 5 minutes
>125% - ≦ 150%: UPS shuts down after 30 seconds
>150%: UPS shuts down after 500 milliseconds
 Transfer time from mains to battery (msec.) Zero 
 Transfer time from Inverter to By-Pass (msec.) Typical 4
 Transfer time from ECO moder to Inverter (msec.) Typical 10
 Number IEC320 C13 sockets 4

 Number of cables supplied with IEC socket and plug

1
 Battery
 Type Maintenance-free lead sealed
 n. batteries 6
 Capacity (Ah) 7
 Voltage (Vdc) 72
 Typical back up time (min.) 10
 Charging time (hours) 3 at 90% of the nominal capacity after a complete discharge
 Charging current (A) 1.5 A maximum
 Charging method Battery management optimization
 Efficiency
 With input mains (%) 93
 In ECO mode (%) 97
 Protections
 Short circuit current (RMS) / Protection time in normal or battery mode 36 A / 100 msec.
 Short circuit current (RMS) / Protection time in Bypass mode 699 A / 7 msec.
 Batteries Switch off at end of discharge 1,65 V/elem. 
 Radio disturbances In accordance with the CE marking and the FCC standard
 Display
 Dot matrix LCD Multi lamguage (10 languages selectable)
 PC interface
 USB 2.0 With HID (Human Interface Device) standard
 RS232 With DB9 connector
 Environmental conditions
 Temperature (°C) from 0 to +40
 Umidity Up to 95% without condensation
 Altitude (meters) ≦ 1.000
 Acoustic noise level
 dBA at 1 meter ≦ 50
 Dimensions and weight
 Dimensions (WxDxH mm) 192 x 428 x 318
 Net weight (kg) 26
 Packing dimensions (WxDxH mm) 111 x 222 x 333
 Gross weight (kg) XX.X

 Technical notes:

  • UPS power is reduced by 10% if the output voltage is selected at 208Vac or by 20% if the output voltage is selected at 200Vac.
  • If used at an altitude above 1,000 meters, the output power is reduced by 1% for every 100 meters up to the maximum limit of 3,000 meters.

Data sheet
1) Manufacturer:
ON LITE
2) Code:
SKOIOT40
3) Typology:
Uninterruptible Power Supply - UPS
4) Technology:
On-Line true double conversion
5) Operating voltage:
One-phase Input and Output